AVAILABLE TO ORDER DuraTech Flat Roof Flashing - 8"

DURAVENT

DuraTech Flat Roof Flashing - 8"

$225.81
(0) Write a Review
SKU:
287109
UPC:
662492557600
Weight:
2.88 LBS
Adding to cart… The item has been added

Use to weather proof the penetration of chimney pipe through a flat roof. Storm Collar required (sold separately). Roof flashing is selected based on pitch of roof. Made of galvalume.

Additional DuraTech Info:

Featuring thermal blanket insulation between dual walls, DuraTech delivers top-tier safety and performance. It maintains a cool outer chimney wall while ensuring high flue gas temperatures for optimal draft. The inner wall is 25% thicker than those in competing chimneys, providing an extra layer of safety. With no need for locking bands or mechanical fasteners, DuraTech’s sleek 1" wall design allows for easy installation through 16" on-center framing. For tight spaces, a Reduced Clearance Square Ceiling Support Box is available (6" diameter DuraTech only). Engineered for continuous operation at 1000°F flue gas temperatures, DuraTech meets rigorous UL standards, including testing at 1400°F for one hour and three ten-minute chimney fire tests at 2100°F.

Applications: 

5”-8” DuraTech is a double-wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas, and zero-clearance fireplaces that are factory-built. 

10”-24” large diameter DuraTech is a 1” wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas.

Materials and Construction: 

5”-8” diameter pipe features inner wall of .020” 430 stainless steel. Outer wall options of .016” 430 stainless steel or .021” galvalume steel.  A thermal blanket insulation is encased between walls. Stainless steel end rings seal the pipe. DuraTech features light weight insulation, twist-lock fittings, support boxes with factory installed starter sections, elbows with 360° swivel base, select black finish pipe lengths,  five-foot length pipe sections, and adjustable pipe lengths. 

10”-24” large diameter DuraTech is a 1” wall, all-fuel chimney system for use with wood stoves, fireplaces, furnaces, boilers, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas

Clearances: 

2” clearance to combustibles. 

Shrouds: 

UL Listed with Duravent shroud specifications. Information available online at www.duravent.com or call and request L157. 

Diameters: 

5”-8” & 10"-12"

Listings: 

c-UL-us Listed to UL 103 HT and CAN/ULC-604 (MH7399)  (Stainless steel outer wall required for oil-burning installations in Canada).

Why Choose DURAVENT

Weatherproof the flat-roof penetration around compatible 8-inch DuraTech chimney with galvalume 8DT-FF flashing. Pair it with the required Storm Collar and correctly integrate the base with the roofing system.

Sized for 8" DuraTech

Designed around insulated DuraTech chimney with an approximately 10" outside diameter. The flashing opening is approximately 10-1/4"; confirm the installed chimney series before ordering.

Galvalume Flat-Roof Base

Galvalume construction forms a broad protective base around the penetration. The square base dimension is approximately 21-5/8". Use this model on flat roofs; choose suitable adjustable flashing for pitched roofs.

Works With a Storm Collar

A compatible DuraTech Storm Collar is required above the flashing and sold separately. Position and seal the collar according to DuraVent instructions to direct water away from the opening.

Coordinates With Chimney Supports

Provides weatherproofing while separate supports carry chimney weight. Maintain DuraTech's 2" clearance to combustibles; the flashing does not reduce clearance or replace a Roof Support or Chimney Cap.

Plan a Weatherproof Flat-Roof Penetration

Match the flashing to the chimney series, nominal diameter, and roof type. Integrate its base with the roofing system, add the required Storm Collar, and coordinate chimney support and clearance for a complete through-the-roof installation.

  • Confirm 8" DuraTech compatibility; order 8DT-FF / stock 810000273 / Modern Hearth SKU 287109.
  • Use on flat roofs. Select separate adjustable DuraTech flashing when the actual roof pitch requires it.
  • Install a compatible Storm Collar above the flashing and integrate the base with the actual roofing system.
  • Provide appropriate structural chimney supports and maintain at least 2" clearance from combustible materials.
  • Inspect the base, roofing, sealant, Storm Collar, and chimney alignment during roof or chimney servicing.
Lifestyle
BrandDURAVENT
SKU287109
MPN8DT-FF
Shipping Weight2.88 LBS
MaterialGalvalume
Pipe Size8" nominal DuraTech chimney; approximately 10" outside diameter; flashing opening approximately 10-1/4"
Component TypeFlat roof flashing; weatherproofing component requiring a separate Storm Collar
ListingApplicable DuraTech chimney system: c-UL-us / UL 103 HT / CAN/ULC-604. Temperature ratings apply to the complete system, not the flashing independently.

Need a different size or configuration?

Additional options may be available. Contact our sales team and we'll help you find the right product.

Product diagrams

Diagram
Diagram
Diagram
Diagram

Frequently Asked Questions

Answers about 8DT-FF compatibility, material, opening size, Storm Collar requirements, chimney support, and flat-roof installation.

Customer Support
What is DuraTech 8" Flat Roof Flashing used for?

It helps weatherproof the penetration where compatible 8-inch DuraTech chimney passes through a flat roof.

What is the DuraVent part number?

The manufacturer part number is 8DT-FF.

What is the flashing made from?

It is constructed from galvalume.

Is a Storm Collar required?

Yes. A compatible DuraTech Storm Collar is required and sold separately.

What size is the chimney opening?

The opening dimension is approximately 10-1/4 inches to accommodate the exterior of 8-inch DuraTech chimney.

Can it be used on a pitched roof?

No. Choose DuraTech adjustable flashing designed for the actual roof pitch.

Does the flashing support chimney weight?

No. Structural chimney support must be provided by the appropriate DuraTech support components.

What clearance does DuraTech require?

Maintain at least 2 inches from combustible materials.

Can it be used with DuraPlus?

No. Use roof flashing specifically designed for the installed chimney system.

Is professional installation recommended?

Yes. Proper roof integration, structural support, chimney clearance, and weatherproofing are important to the completed installation.